* Measuring Range up to 24m (80 feet)
* Accuracy: ±5mm (0.2 inch)
* 4-20 mA + HART Output
* Temperature Range: -22°F to +194°F (-30°C to +90°C)
* Pressure, Max.: 580 psig (40 bar)
* Measurement is Independent of Temperature, Pressure andDensity Variations
* Rod, Cable and Coaxial Probes
* Minimum Dielectric Constant (er) ≥ 1.4
* Removable Graphic Display
* IP67 Protection
Applications
Mono cable / Mono rod / Mono segmented rod
* All high-viscosity liquids
* Clean and contaminated liquids
* For stilling wells (calibration required)
* Conductive foams
* High temperature applications
* Bypass and stilling well applications
Twin cable
* Works with water, solvents, oils or fuels
* Medias with low dielectric constant (er > 1.8)
* Narrow tanks or restricted spaces
* Where minimum dead-zone is needed
* Mounting close to tank wall
Twin rod
* Coated tanks
* Contaminated liquids
* Where minimum dead-zone is needed
* Narrow tanks or restricted spaces
* Slurries, Pulp
Coaxial pipe
* Small vessels or tanks with max. 6m (20 feet) height
* Solvents, LPG, LNG
* Clean liquids with low dielectric constant
* Agitated or flowing liquids
* Contact possible with metallic object or tank wall
* Where no dead-zone allowed